BXQRQ - METHANE IN NITROGEN
- MSDS: BXQRQ
- Manufacturer: SCOTT MARRIN INC
- Product Name: METHANE IN NITROGEN
- National Stock Number: 6830-00N059655
Product Identification
Product ID:METHANE IN NITROGEN
MSDS Date:02/06/1986
FSC:6830
NIIN:00N059655
MSDS Number: BXQRQ
Responsible Party
RIVERSIDE, CA 92507
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 714-653-6780
Cage: GO386
Contractor
Telephone: 714-653-6780
Cage: 55995
Ingredients
NITROGEN
CAS: 7727-37-9
RTECS: QW9700000
Fraction By Weight: SUP DAT
OSHA PEL N/K
ACGIH TLV: ASPHYXIANT
METHANE
CAS: 74-82-8
RTECS: PA1490000
Fraction By Weight: SUP DAT
OSHA PEL N/K
ACGIH TLV: ASPHYXIANT
THE PROPORTIONS OF THE CONSTITUENT GASES. OBTAIN
HYGIENIST SAFETY OFFICER FOR INFORMATION ON NATURE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: ING 1 MAY PRODUCE SUFFOCATION
BY DILUTING CONC OF OXYGEN IN AIR NEC TO SUPPORT LIFE. OXYGEN CONC
<19.5% MUST BE AVOIDED. OXYGEN DEFICIENT ATM MAY PRODUCE DIZZ,
NAUS, VOMIT, LOSS OF CONSCIOUSNES S, & DEATH. DEATH MAY RSLT FROM
ERRORS IN JUDGEMENT, CONFUSION/LOSS OF CONSCIOUSNESS WHICH PREVENTS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: SELF-RESCUE. AT LOW OXYGEN CONCS,
UNCONSCIOUSNESS & DEATH CAN OCCUR IN SEC W/OUT WARNING. ING 2 IS A
SIMPLE ASPHY WHICH IN SUFFICIENTLY HIGH CONCS CAN LOWER PARTIAL
PRESS OF OXYGEN IN AIR EN OUGH TO CAUSE SYSTEMIC EFTS DUE TO OXYGEN
DEFICIENCY. INHALING METHANE CONCS HIGHER THAN 9% CAN PRODUCE NAUS,
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: REMOVE PERS TO UNCONTAM WELL-VENT AREA. SCBA MAY BE
REQUIRED TO PREVENT ASPHY OF RESCUE WORKERS IN LOW OXYGEN ATM. SYMP
QUICKLY SUBSIDE W/INITIATION OF FRESH AIR/OXYGEN INHAL. IF BRTHG
STOPPED, START ARTF RESP. EYES: FLUSH W/POTABLEWATER FOR AT LEAST
15 MIN. SEE MD . SKIN: FLUSH W/COPIOUS AMTS OF WATER. SEE MD .
INGEST: CALL MD IMMED .
Fire Fighting
Lower Limits:5.3%
Upper Limits:14%
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE.
Accidental Release
Spill Release Procedures:VENTILATE ENCLOSED AREAS TO PREVENT OXYGEN
DEFICIENT ATMOSPHERES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:GAS IS IN CYLINDER AT HIGH PRESS. USE
ONLY W/HIGH PRESS EQUIP. USE PRESS REDUCING REGULATOR WHEN
CONNECTING TO LOW PRESS PIPING SYS.
Other Precautions:SECURE CYLINDERS WHEN IN USE. KEEP CYLINDER AWAY FROM
HEAT, FLAME/SPARKS. AVOID DRAGGING, ROLLING/SLIDING CYLINDERS BY
USING SUITABLE HAND TRUCK. FOR ADDNL HNDLG PREC CONSULT COMPRESSED
GAS ASSOCIATIO N PAMPHLET P-1. SHIPMENT OF (SUP DAT)
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED SCBA IS REQUIRED IN
OXYGEN DEFICIENT ATMOSPHERES.
Ventilation:NATURAL OR MECHANICAL TO PREVENT OXYGEN DEFICIENCY.
Protective Gloves:LEATHER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: & A FEELING OF PRESS ON FOREHEAD & EYES. OTHER PREC:
COMPRESSED GAS CYLS FILLED W/OUT PERMISSION OF OWNER IS A VIOLATION
OF FED LAW. IF OXYG DEFICIENT ATMOSPHERES ARE SUSP/CAN OCCUR, USE
MONITORING EQUIP. THE NATURE AND SEVERITY OF THE HAZARD (S)
ASSOCIATED WITH THE GAS MIXTURE WILL VARY WITH (ING 3)
Chemical Properties
Spec Gravity:0.967 (H*2O=1)
Appearance and Odor:COLORLESS AND ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:RETURN CYLINDERS TO MANUFACTURER WITH RESIDUAL
PRESSURE, CYLINDER VALVE CLOSED AND VALVE PROTECTIVE CAP INSTALLED.
DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.